EQ 125 Amp 4-Space 8-Circuit Main Lug Surface Mount Indoor Load Center

  • Aluminum Bus
  • Solid Bus Bar construction
  • Ideal for subfeed applications
  • See More Details

Frequently Bought Together

+
+
Price:

Product Overview

The Siemens EQ 125 Amp 4-Space 8-Circuit Main Lug Indoor Load Center is single phase, 3 wire and rated for a maximum of 240-Volt and has a 100,000 Air. The center is NEMA Type 1 rated for indoor use. This product has a G90 hot-dipped, galvanized-carbon-steel enclosure that helps provide corrosion protection and an additional powder coating of polyester paint, using an electrostatic process, that enhances the corrosion protection and gives a great-looking finish, free of drips and runs.
  • For use as a main lug load center
  • NEMA type 1 rated for indoor use
  • G90 hot-dipped, galvanized-carbon-steel enclosure helps provide corrosion protection
  • Powder coating of polyester paint using electrostatic process enhances corrosion protection and gives a great-looking finish, free of drips and runs
  • 1-piece aluminum buss bar is designed for use only with circuit breakers (not included)
  • Single phase
  • 3-wire
  • 120/240 VAC
  • 100,000 AIR
  • ANSI certified and UL listed
  • Surface mount
  • Combination trim box in 1-package
  • Positive load-side circuit-breaker hook rails
  • Will not accommodate a double-pole GFCI or a circuit breaker with a shunt trip
  • 100 Amp main breaker maximum (not included)
  • Learn More About Electrical Panels Here in our Buying Guide.

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar Individual Subpanels

QO 30 Amp 2-Space 2-Circuit Indoor Main Lug Load Center
current product
EQ 125 Amp 4-Space 8-Circuit Main Lug Surface Mount Indoor Load Center
Homeline 125 Amp 4-Space 8-Circuit Outdoor Main Lug Load Center with Ground BarBest SellerHomeline 100 Amp 6-Space 12-Circuit Outdoor Main Lug Load Center
BrandSquare DSiemensSquare DSquare D
NameQO 30 Amp 2-Space 2-Circuit Indoor Main Lug Load CenterEQ 125 Amp 4-Space 8-Circuit Main Lug Surface Mount Indoor Load CenterHomeline 125 Amp 4-Space 8-Circuit Outdoor Main Lug Load Center with Ground BarHomeline 100 Amp 6-Space 12-Circuit Outdoor Main Lug Load Center
Price
Ratings
(95)
(16)
(22)
(142)
Maximum Amperage (amps)30125125100
Indoor/OutdoorIndoorIndoorOutdoorOutdoor
Number of Spaces2446
Mounting TypePlug-OnBolt OnPlug-OnPlug-On
Number of Circuits28812
Load Center TypeMain LugMain LugMain LugMain Lug
Load center width (in.)3.817.258.888.88
Load center height (in.)6.7213.5014.812.65
View ProductView ProductView ProductView Product

Specifications

Dimensions

Load center depth (in.)
4
Load center height (in.)
13.50
Load center width (in.)
7.25

Details

Electrical Product Type
Main Lug/ Main Lug Kit
Indoor/Outdoor
Indoor
Load Center Mounting Type
Surface
Load Center Type
Main Lug
Maximum Amperage (amps)
125
Mounting Type
Bolt On
NEMA Configuration
NEMA 1
NEMA Configuration Receptacle
No Receptacle
Number of Circuits
8
Number of Spaces
4
Phase Type
1 Phase
Product Weight (lb.)
6 lb
Returnable
90-Day
Voltage (volts)
120/240

Warranty / Certifications

Certifications and Listings
UL Listed
Manufacturer Warranty
1 year

Questions & Answers

6Questions11Answers

i would like to know what knock out sizes are in this box please

Asked by Al July 9, 2020
2
Answers

There are several knockouts available. Please see attached link to our Speedfax catalog. Page 1/30 middle left side picture would be the knockout diagram for this unit. https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/2020-04-02/SpeedFax/SF-17-Sect-01-ALL-web.pdf

What is the appropriate ground bar (kit) for this panel? The only one my local HD carried doesn'...

Asked by Kevin June 9, 2020
1
Answer

ECGB5 is the approved 5 position ground bar and ECGB10 is the 10 position.

There is one question about connecting a 4 wire generator. One answer has the following in the a...

Asked by Tom April 24, 2020
1
Answer

Please see attached you could use the Use Ground Bar ECGB or ECLX kits page 18 https://www.downloads.siemens.com/download-center/Download.aspx?pos=download&fct=getasset&id1=BTLV_67318 and see example installation instructions for 5 position ground bar https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/2019-10-15/Instruction%20Sheet%20Quick%20Guide/SIE_IS_ECGB5.pdf

Hello, How can I connect 220w sauna heater and 110v lights and outlets? How can I use the green s...

Asked by Yo March 28, 2020
2
Answers

E0408ML1125SU is a 4 space 8 circuit maximum load center using Type QP standard size and Type QT duplex breakers. Please consult with a licensed electrician to determine circuit requirements. The green bond screw should be installed for service entrance applications only. It would not be installed for a sub-panel application. Again, consult with an electrician.

How to connect 4 wire 240v (off grid generator ) to this panel?

Asked by FarOut November 23, 2018
2
Answers

To get 240V from this panel, you have to wire the lugs for 240V. From your power source, you wire one hot wire to each of the two main lugs; the white neutral goes to the large neutral lug; and the ground wire goes to the ground bar. Then you install a two pole breaker to goes on two of the stabs. That will give you the 240V - 120V from each pole on the breaker. Then wire your generator from the two pole breaker and neutral/ground bar. But from the way you phrased your question, I assume you are a novice electrician. If so, get someone with experience to assist you or to do it for you. You are working with 240 volt and whatever amps you wire the panel for. For someone who is not exactly sure what they are doing, that can be deadly.

What type of curcuit breaker do I buy for this?

Asked by Mrscott June 4, 2017
3
Answers

Go to Home Depot and look for the Siemens QT breakers. They also have full size breakers in a double pole but I do not know the catalog number. Just look for the mounting feet on the back and the slot plug-in on the front. If you purchase the panel, HD will allow you to open it and you can make sure the breakers you purchase are the correct ones. That may save you another trip.

Customer Reviews

  • 4.8
    out of 16 reviews
  • 100% recommend this product
Filter by:
Showing 1-10 of 16 reviews
by HomeDepotCustomer
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by HomeDepotCustomer
Siemens electrical distribution products are well designed, well manufactured and have always per...
Siemens electrical distribution products are well designed, well manufactured and have always performed well without any problems...I purchase Siemens products whenever possible...
by Lew
Perfect fitting just what I needed...
Perfect fitting just what I needed
by Dale
Used as a sub panel in my garage. Exactly what...
Used as a sub panel in my garage. Exactly what I needed.
by DAVID
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by HomeDepotCustomer
Routing the service wires to the bus bar lugs is...
Routing the service wires to the bus bar lugs is a bit awkward. Would have been nicer to position all the lugs along one edge of the bus block. Also, needing to buy a separate kit just to have a ground bar seems like nickel and diming; it's a little piece of bent sheet metal and some screws; just throw it in the box. To add insult to injury, the only offered locations to mount the ground bar kit block some knockout holes in the enclosure. Overall, though, this seems solid and like it will easily last 100 years.
by MATT
It fit the size that was needed. Perfect for slot needs and amperage needs.
It fit the size that was needed. Perfect for slot needs and amperage needs.
by sacnailer1
by Zeek
Great value...
Great value
by HomeDepotCustomer