Return this item within 90 days of purchase.
Get an answer now with AI
Magic Apron Assistant is an AI virtual assistant. By proceeding, you consent to the recording and use of your information by The Home Depot (and authorized third parties). More information
The Square D Homeline 125 Amp 24-Space 48-Circuit Indoor Convertible Main Lugs Load Center with cover for Plug-on Neutral breakers includes a ground bar and is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings.


Dimensions: H 26.04 in, W 14.25 in, D 3.75 in
Product Depth (in.) | 3.75 in |
|---|---|
Product Height (in.) | 26.04 in |
Product Width (in.) | 14.25 in |
Breaker Box Type | Subpanel |
|---|---|
Connection Type | Neutral |
Indoor/Outdoor | Indoor |
Maximum Amperage (A) | 125 A |
Mounting Type | Flush, Surface |
NEMA Configuration | NEMA 1 |
Number of Circuits | 48 |
Number of Spaces | 24 |
Product Weight (lb.) | 24.49 lb |
Returnable | 90-Day |
Series Type | Homeline |
Voltage (V) | 120/240 V |
Certifications and Listings | UL Listed |
|---|---|
Manufacturer Warranty | Square D warrants its single phase load centers, in a residential application, to be free from defects in material and workmanship under normal care and proper usage for a period of 10 years from the date of installation for HOMELINE load centers when used with the appropriate Square D HOMELINE branch circuit breakers. |
Hello BoxerBob. Homeline arc fault breakers are the only arc fault breakers that this panel will accept. Warm regards. Schneider Electric Customer Care
Hi BoxerBob, QO120PAF is the correct arc fault breaker for this panel. Warm Regards, Schneider Electric Customer Care.
Hi Jimmy, You can remove the installed main lugs and replace it with the QOM2225VH breaker to convert this panel to main breaker. Warm Regards, Schneider Electric Customer Care.
Hi HJS3, QOM125VHCP will fit in this panel Warm Regards, Schneider Electric Customer Care.
Hi HJS3, HOM4RK2LA is the retaining clip for this panel Warm Regards, Schneider Electric Customer Care.
Hi Marc. Yes this is rated for Aluminum and Copper Wires. Warm Regards, Schneider Customer Care
Hi Sparkyquestion, Yes for HOM2448L125PQGC this can be installed upside down. The NEMA 1(indoor) CONVERTIBLE Mains, can be bottom fed by rotating the complete load center and cover. This will NOT cause the labeling to be "upside down", it will just start the circuit counting at the bottom of the cover where the Mains is located, but it will read appropriately. Warm Regards, Schneider Electric Customer Care.
Hi Carlos, The QO124L125G and HOM2448L125PQGC are different load centers. But you can install a QOM1 main breaker to the both of them and they will use the same part number. For a 100A, QOM100VH is the part, and QOM125VH for a 125A main breaker. Warm regards, Schneider Electric Customer Care
Viewing 1-8 of 17