Internet #203030954

Model #HOMRBGK2C

Store SKU #284668

Homeline 150 - 225 Amp Load Center Outdoor Generator Interlock Kit

  • For Homeline main breaker outdoor 150A - 225A electrical panels
  • Choose where to direct generator power to any circuit in the home
  • Includes interlock bracket, retaining bracket, and hardware
  • See More Details

Frequently Bought Together

+
+
Price:
$4695

Product Overview

The Square D by Schneider Electric Homeline Outdoor Cover Generator and QOM2 Frame Size Main Breaker Interlock Kit is used to direct generator power to any circuit within your home. Outdoor unit. Meets UL and ANSI safety requirements. For use on "S2" and "S3" Series NEMA 3R QOM2 load centers. Interlocks a QOM2 2 Pole main circuit breaker of a load center (150-225 A) with a Homeline 2 Pole (15-125 A) branch circuit breaker.
  • Use to interlock the QOM2 main breaker with a double-pole breaker back fed from a generator
  • Helps eliminate the need for a separate generator panel
  • Avoid the inconveniences that an unexpected power outage can cause
  • Includes an interlock bracket, a retaining bracket, a 1-hole drilling template, 3 hex nuts, three 10-32 shoulder screws and an interior mounting screw
  • Wiring diagram and interlock translation labels also provided

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Specifications

Dimensions

Product Depth (in.)
4.5
Product Height (in.)
7.9
Product Width (in.)
4.5

Details

Electrical Product Type
Distribution Load Center / Breaker Accessory
Interruption Type
Standard Trip
Product Weight (lb.)
0.67
Returnable
180-Day

Warranty / Certifications

Certifications and Listings
UL Listed
Manufacturer Warranty
Square D/Schneider Electric warrants equipment manufactured by it to be free from defects in materials and workmanship for eighteen (18) months from date of invoice from Square D/Schneider Electric or its authorized sales channel.

Questions & Answers

40Questions13Answers

How do I find person to set up generator from baax and connect to panel?

Asked by Honora August 14, 2020
1
Answer

Any electrician should be able to set it up for you

transfer interlock

Asked by MFJG August 12, 2020
1
Answer

Hello, Unfortunately, Square D interlock kits can only be used on specific Square D load centers. Regards.

My house has a 2002 panel. # HOMC 30UC. Which kit do I purchase?

Asked by YourHighness August 5, 2020
1
Answer

Hello, The HOMC30UC is the catalog number of the cover. In order to determine if your load center can accept an interlock kit, you need to provide the catalog number and series of the load center. You can use our FAQ article FA274608. It can help you to locate the catalog number and series of your load center. Regards.

Will this interlock kit work with a Square D RC816F150C outdoor CSED

Asked by NYEscapee December 22, 2019
2
Answers

No

I have the Square D all in one panel model SC3042M225PF—what generator interlock kit do I need? ...

Asked by Gbjblue November 8, 2019
2
Answers

It is easy to install with the recommended 3/32 and 3/16 drill bites for metal. Make sure you match the fuse panel amps to the interlock or it won't fit.

The panel is tall with one line of breakers virtually, the main breaker is center of panel. I need interlock for this panel

Asked by butch October 28, 2019
1
Answer

Hello Butch, We need more information on the panel that you have.We encourage you to contact our Product Support at 888-778-2733, option 2 to further assist you on this matter. Warm regards, Schneider Electric Customer Care

Would this interlock it work with an SO2040A200

Asked by Zel October 22, 2019
1
Answer

Zel For the SO2040M200S the generator interlock kit is RCGK2. Regards, Schneider Electric Customer Care

Will this fit a HOM40C40UC?

Asked by Zack September 21, 2019
1
Answer

Hello Zack, That is the part number for the cover of the device. The HOMRBGK2C is usedon “S2” and “S3” Series NEMA 3R QOM2 load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker. Regards.

What interlink kit do I need for Homeline panel cat no HOM30M200C?

Asked by Dan June 2, 2019
2
Answers

The selection of the correct Generator Interlock Kit is dependent upon the Series Number of the Homeline load center. Any other series not listed below does not have a generator interlock kit available. The HOMCGK2C is compatible with any Series S, NEMA Type 1 (indoor); and Series S1, NEMA Type 3R (outdoor), convertible main, main breaker HOMELINE load center that utilizes a QOM2 frame main circuit breaker (150 - 225 ampere). It interlocks the QOM2 2-pole main circuit breaker with a back-fed HOM 2-pole (15-125 ampere) branch circuit breaker. A retaining means is also provided for the back-fed HOM branch breaker. NOTE: Convertible Main Lug Only load centers, that meets the description provided above, could also be used by converting the load center to a Main Breaker device. The HOMRBGK2C is compatible with any Series S2, S3 or S4 NEMA Type 3R (outdoor), convertible main, main breaker HOMELINE load center that utilizes a QOM2 frame main circuit breaker (150 - 225 ampere). It interlocks the QOM2 2-pole main circuit breaker with a back-fed HOM 2-pole (15-125 ampere) branch circuit breaker. A retaining means is also provided for the back-fed HOM branch breaker. NOTE: Convertible Main Lug Only load centers, that meets the description provided above, could also be used by converting the load center to a Main Breaker device. The HOMCRBGK1C is compatible with any Series S, NEMA Type 1 (indoor) or NEMA Type 3R (outdoor), convertible main, main breaker HOMELINE load center that utilizes a QOM1 frame main circuit breaker (100 - 125 ampere). It interlocks the QOM1 2-pole main circuit breaker with a back-fed HOM 2-pole (15-125 ampere) branch circuit breaker. The back-fed generator breaker amperage cannot exceed the amperage of the main breaker. A retaining means is also provided for the back-fed HOM branch breaker. NOTE: Convertible Main Lug Only load centers, that meets the description provided above, could also be used by converting the load center to a Main Breaker device. Regards, Customer Care

Will this work on the SC3042M200PF PANEL?

Asked by Billdego March 26, 2019
1
Answer

No.There is no gernerator interlock kit available for this CSED SC3042M200PF unit. Regards, Customer Care

Homeline 150 - 225 Amp Load Center Outdoor Generator Interlock Kit - page 2

Customer Reviews

  • 22 Customer Reviews
  • 4.6 out of 5 stars overall
100% of customers recommended.
Overall Ratings
5star-icon(16)
4star-icon(4)
3star-icon(1)
2star-icon(0)
1star-icon(1)
Sort By:
Was this helpful?
0
0
Need to return items no longer needed...
Need to return items no longer needed
Was this helpful?
0
0
Worked as expected...
Worked as expected
Was this helpful?
0
0
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
Was this helpful?
0
0
Kit works great does what it is supposed to do....
Kit works great does what it is supposed to do. Easy to install. I didn't need to hire an electrician, but you should if you are not familiar with electricity.
Was this helpful?
0
0
Simple low cost alternative to a manual transfer switch. Requires...
Simple low cost alternative to a manual transfer switch. Requires a very small diameter drill bit for pilot holes
Was this helpful?
0
0
just what I ordered
just what I ordered
Was this helpful?
0
0
5 Star Review
Rating provided by a verified purchaser
Was this helpful?
0
0
This was fairly easy to install but I have done...
This was fairly easy to install but I have done it before with other brands. It would be nice if Square D would pre-dimple the covers like other brands, but they do give you a spacer block which is nice.
Was this helpful?
0
0
This worked on a combination meter/load center. According to...
This worked on a combination meter/load center. According to the manufacturer it was designed to work on a bottom mounted meter panel but it also works on mine with meter mounted on the left side. It should not matter either way as long as it is a 150 to 225 amp main panel.
Was this helpful?