#1 Home Improvement Retailer

Internet #313219937

Model #HOM220CP6

Homeline 20 Amp 2-Pole Circuit Breaker (6-pack)

  • Designed to protect against overloads and short-circuits
  • Residential and single phase commercial use
  • Compatible with Square D Homeline electrical panel and CSEDs
  • See More Details

Frequently Bought Together

+
+
Price:

Product Overview

The Square D by Schneider Electric Homeline 20 Amp 2-pole Circuit Breaker is used for overload and short-circuit protection of your electrical system. This breaker is compatible with Square D's Homeline load centers and CSED devices with available space for a 2-pole breaker. A total of 12 spaces required for entire offering. The ANSI-certified and UL-listed unit is rated for 120-Volt/240-Volt ACand 10,000 AIR. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential and single phase commercial market, Homeline products offer everything you need to distribute electricity throughout your home.

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar Double Pole Breakers

current product
Homeline 20 Amp 2-Pole Circuit Breaker (6-pack)
Top RatedHomeline 50 Amp 2-Pole Circuit Breaker (6-pack)QO 20 Amp 2-Pole Circuit Breaker (6-pack)QO 50 Amp 2-Pole Circuit Breaker (6-pack)
BrandSquare DSquare DSquare DSquare D
NameHomeline 20 Amp 2-Pole Circuit Breaker (6-pack)Homeline 50 Amp 2-Pole Circuit Breaker (6-pack)QO 20 Amp 2-Pole Circuit Breaker (6-pack)QO 50 Amp 2-Pole Circuit Breaker (6-pack)
Price
Ratings
(1171)
(1171)
(799)
(799)
Interruption TypeStandard TripStandard TripStandard TripStandard Trip
Breaker TypeDouble PoleDouble PoleDouble PoleDouble Pole
Pack Size6666
Power Distribution FeaturesNo Additional FeaturesNo Additional FeaturesTrip IndicatorTrip Indicator
Maximum Amperage (amps)20502050
Mounting TypePlug-OnPlug-OnPlug-OnPlug-On
Electrical Product TypeBreakerBreakerBreakerBreaker
Voltage (volts)120/240120/240120/240120/240
View ProductView ProductView ProductView Product

Specifications

Dimensions

Product Depth (in.)
2.98
Product Height (in.)
3.13
Product Width (in.)
2

Details

Breaker Type
Double Pole
Electrical Product Type
Breaker
Interruption Type
Standard Trip
Maximum Amperage (amps)
20
Mounting Type
Plug-On
Number of Poles
2
Pack Size
6
Power Distribution Features
No Additional Features
Product Weight (lb.)
0.67
Returnable
90-Day
Voltage (volts)
120/240

Warranty / Certifications

Certifications and Listings
UL Listed
Manufacturer Warranty
Square D warrants its branch circuit breakers to be free from defects in material and workmanship under normal care and proper usage in a residential installation, for the lifetime of the Homeline load center in which it is installed.

Questions & Answers

202Questions28Answers

what is the largest size alum cable the 60amp breaker will accept. not for load but the biggest cable terminal can.hsndle

Asked by Markwc June 16, 2021
0
Answers

Does square d make a replacement CB for a Murray 100 amp panel?

Asked by Sparky May 19, 2021
2
Answers

You can only install the HOM220CP in HOM Square D load centers. Regards, Schneider Electric Customer Care.

What is the official temperature rating on this product? For example, AL 1-1-1-3 SER is rated > ...

Asked by Daniel May 10, 2021
2
Answers

The breaker itself has no temperature rating, but I believe the lugs are rated at 75C. When you see a building wire with a 90C rating, that rating is only used when derating is required.

Will this replace a square D ys-7699 breaker

Asked by Bunkerbob1 May 6, 2021
3
Answers

YS-7699 is not a catalog number. HOM230CP is a HOM breaker, 2 poles, 30A. You can install it in HOM load centers. Regards, Schneider Electric Customer Care.

Is this breaker compatible in a Thomas and Betts panel? The house was built in 97.

Asked by Tank April 29, 2021
3
Answers

I found a cross reference that shows Homeline breakers do crossover to Thomas and Betts. There is a good chance this will fit! If not you can take it back to Home Depot for a refund. https://www.platt.com/CutSheets/Eaton%20Distribution/Breakers-ClassifedType.pdf

Will this fit in a eaton type br box

Asked by Teera March 31, 2021
5
Answers

I think it will. Their physical shape appears to be indentical. “Homeline breakers are made to fit in most interchangeable panels”. There is an Eaton doc that says they are interchangeable.

Will this fit into a General Electric panel box bus bar

Asked by yardman March 26, 2021
2
Answers

No. You can only use HOM250GFICP in HOM Square-D load centers. Regards, Schneider Electric Customer Care.

Is this a resettable breaker?

Asked by Mx6 March 2, 2021
5
Answers

Yes it is. When it trips the lever/switch will be halfway between on and off. Just flip it all the way off first and then flip it on.

can’t find rhis breaker anywhere. when will it be available again? there is none at the stores an...

Asked by Tom January 30, 2021
2
Answers

Call your local Square D distributor, they have them.

Will this breaker substitute for a Challenger 2 pole 30 amp type C 120/240v breaker?

Asked by REthePE January 26, 2021
4
Answers

I would guess no. This breaker is type HOM, while the Challenger is type C. While there's an outside chance that it could fit in your panel, you should always use the type of breaker that's called for by the panel manufacturer. There should be a sticker or decal in the breaker panel that says what type of breakers should be used.

Homeline 20 Amp 2-Pole Circuit Breaker (6-pack) - page 2

Customer Reviews

  • 4.8
    out of 1,171 reviews
  • 98% recommend this product
Filter by:
Showing 1-10 of 1,171 reviews
The breaker was exactly as described. Fitted properly into the breaker box and it works as a bre...
The breaker was exactly as described. Fitted properly into the breaker box and it works as a breaker.
by HomeDepotCustomer
1 person found this helpful
The perfect replacement for the old one that lasted long enough
The perfect replacement for the old one that lasted long enough
by Dennis
1 person found this helpful
Exactly as expected....
Exactly as expected.
by Abe
Works like it should
Works like it should
by Mike
1 person found this helpful
Used this on a 5.5kw electric hot water heater.
Used this on a 5.5kw electric hot water heater.
by Treefarmer
1 person found this helpful
Great quality at an affordable price! Thanks home depot!
Great quality at an affordable price! Thanks home depot!
by Ricksld
1 person found this helpful
Totally satisfaction, I bought this to replace a sub panel breaker that was a generic brand for m...
Totally satisfaction, I bought this to replace a sub panel breaker that was a generic brand for my Home line with recommend that you put the same breaker as your panel.
by
2 people found this helpful
Solid product. Straight forward install. Common sence. Increased to 30amp for my generator. 10 mi...
Solid product. Straight forward install. Common sence. Increased to 30amp for my generator. 10 minutes max.
by Sw
3 people found this helpful
This is a good product but like most materials in the trades their way way too expensive. So far ...
This is a good product but like most materials in the trades their way way too expensive. So far I've had no problem with this breaker easy to install. Time will tell.
by Ronald
5 people found this helpful
Just as an FYI before you buy or replace any breakers in your new or existing panel; it's never a...
Just as an FYI before you buy or replace any breakers in your new or existing panel; it's never a good idea to install a breaker that doesn't match the specs for your panel. In other words only use Square D breakers in a Square D panel and match the type of breaker to what the panel calls for. The same goes for any breaker and panel combo. If you have any doubt contact a qualified electrician. Some breakers will interchange and fit in other panels but they are not approved and may cause real issues down the road. This is especially true when a home is undergoing a home inspection prior to sale. Most inspectors will call out incompatible breakers in a panel and call for there replacement. I have always liked the design of Square D products and they are available at the most locations across the country at very reasonable cost. The breakers are very easy to install and are easy to troubleshoot. When there is a fault these breakers give a very positive loud click when a fault happens and flip into the off position side of the beaker. Since these are so inexpensive, I keep a few different amperage breakers on hand if they ever need replacement at odd hours. Installing these into a panel is quick and easy. Always turn off the main breaker on the panel and test that the power is truly off on each of the breakers before you start (you never know what someone has done before). These breakers slip under plastic lugs in the panel then snaps into the load buss bar(s). Since mine is a twin 15 amp breaker it picks up power from both buss bars to provide 220 volt power. The breaker has nice large terminal screws and wire hold downs. The terminal screw is torqued down to 36 In pounds, per manufacture specs (15 thru 30 amp breakers) with either a large straight screwdriver 3/8" wide blade or a #2 square bit. If you have any reservations about doing this type of work, please contact a qualified electrician to preform the work.
by OutbackJoe
16 people found this helpful