Brand | Square D | Square D | Square D | Square D |
Name | Homeline 20 Amp Single-Pole Plug-On Neutral Combination Arc Fault Circuit Breaker | Homeline 15 Amp Single-Pole Plug-On Neutral Dual Function (CAFCI and GFCI) Circuit Breaker | Homeline 20 Amp Single-Pole Dual Function (CAFCI and GFCI) Circuit Breaker | Homeline 20 Amp Single-Pole Plug-On Neutral Dual Function (CAFCI and GFCI) Circuit Breaker |
Price | $4119 | $4699 | $4948 | $5024 |
Ratings | (119) | (119) | (461) | (119) |
Interruption Type | CAFCI | Dual Function (C/AFCI and GFCI) | Dual Function (C/AFCI and GFCI) | Dual Function (C/AFCI and GFCI) |
Maximum Amperage (amps) | 20 | 15 | 20 | 20 |
Breaker Type | Single Pole | Single Pole | Single Pole | Single Pole |
Power Distribution Features | No Additional Features | No Additional Features | No Additional Features | No Additional Features |
Pack Size | 1 | 1 | 1 | 1 |
Voltage (volts) | 120/240 | 120/240 | 120/240 | 120/240 |
Mounting Type | Plug-On Neutral | Plug-On Neutral | Plug-On | Plug-On Neutral |
View Product | View Product | View Product | View Product |
![]() | ![]() | ![]() | ![]() | |
Brand | Square D | Square D | Square D | Square D |
Name | Homeline 20 Amp Single-Pole Plug-On Neutral Combination Arc Fault Circuit Breaker | Homeline 15 Amp Single-Pole Plug-On Neutral Dual Function (CAFCI and GFCI) Circuit Breaker | Homeline 20 Amp Single-Pole Dual Function (CAFCI and GFCI) Circuit Breaker | Homeline 20 Amp Single-Pole Plug-On Neutral Dual Function (CAFCI and GFCI) Circuit Breaker |
Price | $4119 | $4699 | $4948 | $5024 |
Ratings | (119) | (119) | (461) | (119) |
Interruption Type | ||||
Maximum Amperage (amps) | ||||
Breaker Type | ||||
Power Distribution Features | ||||
Pack Size | ||||
Voltage (volts) | ||||
Mounting Type | ||||
View Product | View Product | View Product | View Product |
Nuisance trips can occur whether in a neutral bonded main panel or neutral isolated subpanel, however nuisance trips are generally rare.
This is a combo it is a Arc Fault and a Circuit Breaker. Arc Fault is now require in many areas for bedrooms and lighting. Regular circuit breakers can still be use in very limit cases depending on codes. The combo like sku 1000-039-744 has three, circuit breaker, arc fault, and ground fault (use in wet locations, garages and sink areas). Some code require one or the other depending on your location.
No, you cannot tie two breakers with a handle tie. I would use a 2-pole GFCI breaker and forget the AFCI requirement in latest codes. You are grandfathered and do not need the AFCI protection.
No they need single slot
This is the cover catalog number that fits multiple Homeline panel both Non PON and Standard Homeline Load Centers. Will need to confirm the catalog number for load center.The Plug-On CAFI breakers are designed to ONLY be used with the Plug-ON Neutral Load Centers. No, the Plug-On Neutral CAFI breakers are NOT for use in older load centers, because they wouldn't work in an older panel. Regards, Customer care
They make a double breaker or use regular handle ties. Both works.
Dryer circuits are not required to be arc fault protected.
For quantity pricing you should contact Home Depot. No one on a public forum can quote discount pricing.
You’re not permitted to double tap any type breaker...period. One lug, one wire.
Yes and most HD stores stock them.