Brand | Square D | Square D | Square D | Square D |
Name | Homeline 100 Amp 20-Space 40-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover - Value Pack | Homeline 200 Amp 30-Space 60-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover - Value Pack | Homeline 200 Amp 40-Space 80-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover - Value Pack | QO 200 Amp 2-Pole Outdoor Circuit Breaker Enclosure with QOM2200VH Breaker |
Price | $7274 | $12573 | $13900 | $13905 |
Ratings | (355) | (355) | (355) | (49) |
Indoor/Outdoor | Indoor | Indoor | Indoor | Outdoor |
Number of Spaces | 20 | 30 | 40 | 0 |
Number of Circuits | 40 | 60 | 80 | 1 |
Maximum Amperage (amps) | 100 | 200 | 200 | 200 |
Mounting Type | Plug-On Neutral | Plug-On Neutral | Plug-On Neutral | Bolt On |
Load center height (in.) | 20.92 | 33.78 | 39.37 | 16.18 |
Load center depth (in.) | 3.75 | 3.75 | 3.75 | 4.12 |
Load center width (in.) | 14.25 | 14.25 | 14.25 | 6.92 |
Electrical Product Type | Load Center and Breaker Kit | Load Center and Breaker Kit | Load Center and Breaker Kit | Load Center and Breaker Kit |
View Product | View Product | View Product | View Product |
![]() | ![]() | ![]() | ![]() | |
Brand | Square D | Square D | Square D | Square D |
Name | Homeline 100 Amp 20-Space 40-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover - Value Pack | Homeline 200 Amp 30-Space 60-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover - Value Pack | Homeline 200 Amp 40-Space 80-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover - Value Pack | QO 200 Amp 2-Pole Outdoor Circuit Breaker Enclosure with QOM2200VH Breaker |
Price | $7274 | $12573 | $13900 | $13905 |
Ratings | (355) | (355) | (355) | (49) |
Indoor/Outdoor | ||||
Number of Spaces | ||||
Number of Circuits | ||||
Maximum Amperage (amps) | ||||
Mounting Type | ||||
Load center height (in.) | ||||
Load center depth (in.) | ||||
Load center width (in.) | ||||
Electrical Product Type | ||||
View Product | View Product | View Product | View Product |
Yes, the 100 amp main breaker will accept #2 conductors.
Yes, the 200 amp main breaker is factory installed.
No ground bar is included, purchase it separately.
Use just about any Homeline breaker. No other breakers from other manufacturers are UL Listed for this panel.
This panel has two neutral bus bars for both plug-on neutrals and for screw terminal neutrals. It's ground bars that must be purchased separately.
Yes, you still have to install a 50 -70 amp breaker as a main disconnect. I believe that panel is available without a Main installed.
Yes, this panel is approved to be inverted for bottom feed applications.
This panel has 40 spaces and will accept 40 full sized 1" breakers or 40 tandem 1" breakers for a total of 80 circuits. Indoor means this is a NEMA 1 panel suitable to be installed indoors. Main breaker means the 200 amp main breaker is factory installed.
Yes, this panel can be installed as a subpanel. You'll need a 4-wire feed and will also need to purchase a ground bar kit separately. Do not install the green neutral bonding screw, the neutral must be isolated from the grounded panel box. If the garage is detached you will also need to install at least one ground rod connected to the ground bar with #6 copper Grounding Electrode Conductor.
Possibly, but generally only skilled electricians should attempt to do so.