Return this item within 90 days of purchase.
Get an answer now with AI
AI-generated from the text of manufacturer documentation. To verify or get additional information, please contact The Home Depot customer service.
The Square D Homeline 225 Amp 40-Space 80-Circuit Indoor Convertible Main Lugs Load Center with cover for Plug-on Neutral breakers is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings.

Dimensions: H 39.37 in, W 14.25 in, D 3.75 in
Product Depth (in.) | 3.75 in |
|---|---|
Product Height (in.) | 39.37 in |
Product Width (in.) | 14.25 in |
Breaker Box Type | Subpanel |
|---|---|
Connection Type | Neutral |
Indoor/Outdoor | Indoor |
Maximum Amperage (A) | 225 A |
Mounting Type | Flush, Surface |
NEMA Configuration | NEMA 1 |
Number of Circuits | 80 |
Number of Spaces | 40 |
Product Weight (lb.) | 36 lb |
Returnable | 90-Day |
Series Type | Homeline |
Voltage (V) | 120/240 V |
Certifications and Listings | UL Listed |
|---|---|
Manufacturer Warranty | Square D warrants its single phase load centers, in a residential application, to be free from defects in material and workmanship under normal care and proper usage for a period of 10 years from the date of installation for HOMELINE load centers when used with the appropriate Square D HOMELINE branch circuit breakers. |
Hi Martin, The enclosure of HOM816L125PC is NEMA 1 rated so it can only be used indoors. Warm Regards, Schneider Electric Customer Care.
Hi Tadek, Yes you can feed the panel with 4 wires. You'll need to install the ground bar PK9GTA to isolate the ground wire from the neutral. Warm Regards, Schneider Electric Customer Care.
Hi Mali HOM1224L125PC will accept wire sizes 6–2/0 AWG Al wires or 6–1/0 AWG Cu wires. Warm Regards, Schneider Electric Customer Care.
Hi Ron6519, Homeline load centers will only accept HOM type breakers. Warm Regards, Schneider Electric Customer Care.
Hello Jayson. HOM816L125PC can handle 4-wire system if that is composed of 2 hot wires, 1 neutral and 1 ground. It is does not "need" a 4-wire system. Warm regards. Schneider Electric Customer Care
Hi David Yes. HOM816L125PC can be mounted upside down for bottom feeding. Warm Regards, Schneider Electric Customer Care.
Hello Gene. Yes either a 2-pole 50A back-fed main breaker or a 50A main breaker kit (Catalog number QOM50VH) can be used as a 50A main breaker for HOM816L125PC. As long as the main breaker will not be overloaded of the loads that would be connected. Warm regards. Schneider Electric Customer Care
Hi Yes. The HOM816L125PC can accept 4 AWG CU or 2 AWG AL feeder wires. You can install a QOM125VHCP in this panel so it will have it's own main disconnect. Warm Regards, Schneider Electric Customer Care.
Viewing 1-8 of 68
4.8 out of 5