The Square D by Schneider Electric Homeline 30 Amp Two-Pole GFCI circuit breaker is designed for overload and short-circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 mA or more. This breaker is compatible with Square D Homeline load centers and CSED devices. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 AIR. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential market, Homeline products offer everything you need to distribute electricity throughout your home.
Dimensions: H 3.13 in, W 2 in, D 2.98 in
Product Depth (in.) | 2.98 in | Product Height (in.) | 3.13 in |
---|---|---|---|
Product Width (in.) | 2 in |
AIC Rating | 10000 | Breaker Type | Standard |
---|---|---|---|
Connection Type | Pigtail | Interruption Type | GFCI |
Maximum Amperage (A) | 30 A | Mounting Type | Plug-On |
Number of Poles | Quad | Number of Spaces | 2 |
Pack Size | 1 | Product Weight (lb.) | 1.16 lb |
Returnable | 90-Day | Series Type | Homeline |
Trip Unit | Electronic | Voltage (V) | 120/240 V |
Certifications and Listings | UL Listed | Manufacturer Warranty | Square D warrants its branch circuit breakers to be free from defects in material and workmanship under normal care and proper usage in a residential installation, for the lifetime of the Homeline load center in which it is installed. |
---|
Hi Jeff, HOM2100C will take (1) 4–2/0 AWG wires. Warm Regards, Schneider Electric Customer Care
Hi sparky, Yes, a 2 pole 30A breaker can handle 1 wire per lug: (1) #14 - #8 AWG Aluminum or Copper. Warm regards, Schneider Electric Customer Care
Hi Woods, You might be looking for a breaker that can be backfed, and the HOM250CP or HOM250 can be backfed. But this depends on what panel you are using. Please reach out to us via chat to confirm if you need to use HOM1RK , HOM4RK2LA, or HOM4RK2HA as a retaining kit to backfeed the breaker. This completely depends on what panel you are using. https://www.se.com/us/en/work/support/customer-care/contact-schneider-electric.jsp Warm regards. Schneider Electric Customer Care
Hi Mikie! The CP stands for commercial packaging. The HOM250GFI and HOM250GFICP are identical, the packaging is the only thing that is different. Warm regards, Schneider Electric Customer Care
Hi Bill, Yes a 2 pole breaker will (depending on application) power/draw power from both of the bus bars in a 240V load center or enclosure. Warm Regards, Schneider Customer Care.
Hi none, Max wire size for 2 pole 80A - 125A branch breaker for HOMELINE is 4–2/0 AWG for both AL and Cu. Warm Regards, Schneider Customer Care.
Hi Wayne! Unfortunately, no. The HOM2100 or any other homeline branch breaker are only UL tested and approved to be used in a Homeline panel. Each manufacturer has it's own UL listings for their specific products based on their specific product line and their specific combination of products. Warm regards. Schneider Electric Customer Care
Hi Brook! I am afraid it might not physically fit and it won't pass you from an inspection. Each manufacturer has it's own UL listings for their specific products based on their specific product line and their specific combination of products. A homeline panel is only intended to accept a homeline panel, same goes to other brands. Warm regards, Schneider Electric Customer Care