#1 Home Improvement Retailer

Internet #100174454

Model #QO24L60NRNM

Store SKU #697802

QO 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center with Non-Metallic Enclosure and Neutral

  • QO Interiors and components provide time-tested reliability
  • Compatible with Square D QO standard circuit breakers
  • Non-metallic outdoor enclosure with ground bar & aluminum bus bar
  • See More Details

Frequently Bought Together

+
+
Price:

Product Overview

Shop for compatible circuit breakers.
The Square D QO 60 Amp 2-Space 4-Circuit Fixed Main Lugs Outdoor Load Center is UL listed for residential, commercial and industrial power distribution. This load center is built with a rugged thermoplastic interior and an aluminum bus bar plated for reliability. QO load centers are tested and compatible with Square D QO standard circuit breakers and CTL-type tandems. Square D QO load centers are the "World's Finest" designed with industry leading features for flexible application. QO breaker boxes include features engineered for fast installation and wire savings.
  • Learn about general NEC 2020 updates. Contact your local building inspector for adoptions and details.
  • Square D QO 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center with Non-Metallic Enclosure and Neutral
  • Includes a non-metallic outdoor cover and factory-installed PK4GTA ground bar
  • Accommodates plug-on secondary surge arrestor (sold separately)
  • Compatible with Square D QO standard circuit breakers and CTL-type tandems only
  • Main feeders terminate from the top, feeders can enter from any direction, however, device cannot be rotated
  • Single phase, Outdoor Main Lug QO Breaker Box
  • Rated 120/240 VAC and 10,000 AIR short circuit current rating
  • Rainproof non-metallic breaker box rated for outdoor use
  • Thermoplastic interior is among the most rugged in the industry
  • Slot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque
  • Learn More About Electrical Panels Here in our Buying Guide.
  • California residents

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar Individual Subpanels

EQ 60 Amp 2-Space 4-Circuit Main Lug Surface Mount Load Center
current product
QO 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center with Non-Metallic Enclosure and Neutral
Homeline 125 Amp 4-Space 8-Circuit Outdoor Main Lug Load Center with Ground BarQO 100 Amp 6-Space 12-Circuit Outdoor Main Lug Load Center with Cover
BrandSiemensSquare DSquare DSquare D
NameEQ 60 Amp 2-Space 4-Circuit Main Lug Surface Mount Load CenterQO 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center with Non-Metallic Enclosure and NeutralHomeline 125 Amp 4-Space 8-Circuit Outdoor Main Lug Load Center with Ground BarQO 100 Amp 6-Space 12-Circuit Outdoor Main Lug Load Center with Cover
Price
Ratings
(17)
(20)
(23)
(50)
Maximum Amperage (amps)6060125100
Indoor/OutdoorIndoorOutdoorOutdoorOutdoor
Number of Spaces2246
Mounting TypeBolt OnPlug-OnPlug-OnPlug-On
Number of Circuits44812
Load Center TypeMain LugMain LugMain LugMain Lug
Load center width (in.)66.528.888.88
Load center height (in.)118.7914.812.65
View ProductView ProductView ProductView Product

Specifications

Dimensions

Load center depth (in.)
3.9
Load center height (in.)
8.79
Load center width (in.)
6.52

Details

Electrical Product Type
Main Lug/ Main Lug Kit
Indoor/Outdoor
Outdoor
Load Center Mounting Type
Surface
Load Center Type
Main Lug
Maximum Amperage (amps)
60
Mounting Type
Plug-On
NEMA Configuration
NEMA 3R
NEMA Configuration Receptacle
No Receptacle
Number of Circuits
4
Number of Spaces
2
Phase Type
1 Phase
Product Weight (lb.)
1.47
Returnable
90-Day
Voltage (volts)
120/240

Warranty / Certifications

Certifications and Listings
UL Listed
Manufacturer Warranty
Square D warrants its QO branch circuit breakers to be free from defects in material and workmanship under normal care and proper usage in a residential installation, for the lifetime of the load center in which it is installed. QO brand load centers are also covered under the same lifetime warranty.

Questions & Answers

13Questions22Answers

Will this accommodate Model #: QO250GFICP breaker for a hot tub? If, no, which small, outdoor breaker box will?

Asked by Neffy July 16, 2020
1
Answer

Hello Neffy, Yes, it will accommodate the QO250GFICP. If you don't have this QO24L60NRNM box yet, you can get the QOE250GFINM instead, its consists of a QO250GFI Ground Fault Circuit Interruptor installed in a QO24L60NRNM non-metallic enclosure. Warm regards, Schneider Electric Customer Care.

I see 2 bars inside this box. Which bar is for neutral? Also, are the bars suppose to be bonded...

Asked by Ray February 17, 2020
1
Answer

Hello Ray, Facing it, neutral bar is at the right and ground bar at the bottom center. When a load center is used as Service Equipment, the NEC requires that the neutral shall be bonded to the metal box. The Service Equipment is identified by the fact it includes the first disconnect of the incoming power from the Utility. Regards, Schneider Electric Customer Care.

I'm hooking up a 220 volt 20 amp mini split will this box work

Asked by January 26, 2020
2
Answers

Hello, You can use a QO 20A breaker with this load center. Regards, Schneider Electric Customer Care

I am looking at using this box with a 50 AMP GFI breaker for my hot tub installation any issues?

Asked by CD February 24, 2019
4
Answers

Yes.

Will this hold a 2 -30amp 2 pole breakers

Asked by Brian January 6, 2019
2
Answers

Just one two pole circuit breaker.

can I run 220 to this box and run 110 to 4 eclectic plugs

Asked by happy January 10, 2018
4
Answers

Yes, as long as you run a neutral along with your 220.

Pretty confused here....I can see from the picture clearly that two single pole breakers fit. Soo, how 4 circuits?

Asked by Electrician October 28, 2017
2
Answers

Two

Can both a 30 amp 2 pole breaker for a 220 volt circuit and a 20 amp 2 pole breaker for a 110 vo...

Asked by Stillearning September 14, 2017
2
Answers

My question was: can I install a 30 amp 2 pole breaker and 20 amp 1 pole breaker at the same time in this panel? The panel is described as a 2-space panel but will it hold both the 30 amp 2 pole breaker and the 20 amp single pole breaker at the same time?

Does this come with the 60 amp breaker in it?

Asked by jeff June 4, 2017
2
Answers

No you must provide the circuit breaker. Some disconnects DO come with Breaker though. Primarily labeled as a spa circuit breaker kit.

Will this work as a solar panel combiner box?

Asked by Stan January 29, 2016
2
Answers

Yes, this will work.

QO 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center with Non-Metallic Enclosure and Neutral - page 2

Customer Reviews

  • 4.6
    out of 20 reviews
  • 100% recommend this product
Filter by:
Showing 1-10 of 20 reviews
Needed a compact outdoor remote load center for our pool equipment - GFIC for pool pump and pool ...
Needed a compact outdoor remote load center for our pool equipment - GFIC for pool pump and pool light. This fit the bill perfectly, although the circuit breakers that fit are pretty pricey!
by sbourg
After. Gutting it worked fine....
After. Gutting it worked fine.
by HomeDepotCustomer
I needed a new 50 amp breaker when I installed...
I needed a new 50 amp breaker when I installed an inverter in my 5th wheel. I purchased this and a compatible breaker to go with it. The setup worked perfectly for what I needed.
by Wingy14
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by HOMER
Very well built
Very well built
by LJ
Works as expected. Nice......
Works as expected. Nice...
by JET
your store is a great place to shop. easy to...
your store is a great place to shop. easy to find items, friendly employees, clean place
by HomeDepotCustomer
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by HomeDepotCustomer
Their where no breakers for it anywhere...
Their where no breakers for it anywhere
by HomeDepotCustomer
Response from SchneiderCustomerCareAug 6, 2019
If you are experiencing trouble locating the proper breakers for this loadcenter please contact our Customer Care Center at 888-778-2733. We would be happy to review the breakers that this unit accepts and offer options for purchasing.
Thank you,
Schneider Electric Customer Care SquareD
Great product and worked well.The only reason for the 4...
Great product and worked well.The only reason for the 4 stars is that there was not enough knockouts in the bottom. I pedestal mounted the box and needed three 3/4" conduits to enter the bottom. I had to add an LB on the side.It worked out OK but required another trip to the store.
by Douglas
1 person found this helpful