3/4 in. x 100 ft. Electrical Nonmetallic Tubing Conduit Coil, Blue

$6288
/roll
Apply Now
Pay $37.88 after $25 OFF your total qualifying purchase upon opening a new card. info
Apply for a Home Depot Consumer Card
  • Lightweight and Bendable
  • Free from sharp edges
  • For use in walls, floors and non-plenum ceilings
  • View More Details
Store
0 in stock
caret

Product Details

The Carlon 3/4 in. x 100 ft. Electrical Non-Metallic Tubing is a flexible raceway for use in floors, walls and non-plenum ceilings. It is made with PVC and is designed to replace EMT conduit, flexible metal conduit and other raceway or cable systems. The tubing should be used with Carlon blue cement.
  • Product is coiled in a 100 ft. roll 3/4 in. size I.D. is 0.76 and the O.D. is 1.05 with a minimum bend radius is 6 in.
  • Color blue indicates it is used for electrical power circuits product is also known as Smurf tube
  • Carlon ENT tubing can also be used to run low-voltage wiring devices such as coax cable, computer cable and telephone cable
  • Carlon PVC cement is recommended for use with ENT tubing along with fittings and boxes
  • UL listed
  • Return Policy

Additional Resources

From the Manufacturer

caret

Specifications

caret

Questions & Answers

11Questions
caret
Q:Can it be cut at store? Sold by the foot?
by|Dec 21, 2022
2 Answers
Answer This Question

A:  It’s sold by the roll, however you can purchase shorter rolls. 

by|Dec 24, 2022

    A:  It is easily cut with knife or hacksaw. I don't think it's sold by the foot. It's always measure twice and add 5% for mistakes!

    by|Dec 24, 2022
      caret
      Q:How does this form in direct sunlight? Durabilty and heat?
      by|May 6, 2021
      1 Answer
      Answer This Question

      A:  This is not a product for outdoors installation needs to be protected in a building.

      by|Jul 21, 2022
        3 found this answer helpful
        caret
        Q:Can 3x lines of ethernet Cat6 fit inside 3/4" Carlon ENT or should I go with 1" ?
        by|Mar 30, 2021
        2 Answers
        Answer This Question

        A:  3x lines of cat6 will be no issue. Obviously you can’t pull 3x through with the ends terminated though, you must terminate after pulled through.

        by|Jan 9, 2023
          3 found this answer helpful

          A:  I've pulled 6 through it without an issue. I also pulled 4 RG6-quad shield through it without an issue.

          by|Jan 9, 2023
          5 found this answer helpful
          caret
          Q:Can I run 8/3 thhn for a sub panel. im curuius how it would turn out.
          by|Sep 4, 2020
          1 Answer
          Answer This Question

          A:  You would need to check with your local code.

          by|Nov 2, 2020
            Showing 1-4 of 11
            caret

            Customer Reviews

            4.7 out of 5
            (83)
            • 4.7
              out of 83 reviews
            • 92%recommend this product
            Filter by:
            Showing 1-10 of 83 reviews
            Just say yes to Smurf Tube! I've been using this stuff for years when I need to run network cable...
            Just say yes to Smurf Tube! I've been using this stuff for years when I need to run network cables in places that need protection. Most recently, I needed to run drops in a very old hardware store where the only way to get the cables to the location was going through a dirt crawl space that is not weather sealed. I have 3 90º turns and some other funny angles. and the two cables pulled through the 80' of conduit as smooth as could be. The rib construction helps greatly reduce friction. Pro Tips: Secure it every 4 to 5'. You can hook a shopvac to one end, tie a small wad of some kind string, and suck it right though the tube. Stick with the 3/4", even if you only need the 1/2", it can helps things pull better. If things are pulling a bit hard, you can use pulling wax/gel, but hand soap or gel hand sanitizer works well, too. For the 3/4", 1-1/8" hole is the perfect size for it to slip though but remain snug. If your penetration goes between inside and outside, seal around it with silicone.
            by
            • Pro
            • Verified Purchase
            • Recommended
            4 found this review helpful
            Good value, better price than elsewhere
            It's smurf tube - it does what it's supposed to. It was cheapest here.
            by
            • DIY
            • Verified Purchase
            • Recommended
            3 found this review helpful
            Good product perfect choice....
            Good product perfect choice.
            by
            • Verified Purchase
            Once I got the ENT on site and unrolled coil...
            Once I got the ENT on site and unrolled coil Realized there was just over 50ft on coil not 100ft But I needed 30ft right then so didn't bring it back.
            by
            • Verified Purchase
            I have never had any issues with nonmetallic tubing from...
            I have never had any issues with nonmetallic tubing from home depot. I only bought this because my distributor was out of inch and a half nonmetallic tubing. Home Depot really needs to stock all sizes of tubing in their stores.
            by
            • Verified Purchase
            Quality product. Just a tangled mess trying to unwind because...
            Quality product. Just a tangled mess trying to unwind because the way it's cooked
            by
            • Verified Purchase
            yes i am please to order this product from your...
            yes i am please to order this product from your company.
            by
            • Verified Purchase
            by
            • Verified Purchase
            Rating provided by a verified purchaser...
            Rating provided by a verified purchaser
            by
            • Verified Purchase
            Rating provided by a verified purchaser...
            Rating provided by a verified purchaser
            by
            • Verified Purchase
            Showing 1-10 of 83 reviews

            Frequently Bought Together

            +
            +
            Price:
            $6288

            Compare Similar Boxes & Brackets

            current product
            3/4 in. x 100 ft. Electrical Nonmetallic Tubing Conduit Coil, Blue
            11.8 in. L x 10 in. W x 5.5 in. H Polycarbonate Clear Screw Top Cabinet Enclosure with Gray Bottom11.8 in. L x 10 in. W x 7.5 in. H Polycarbonate Clear Screw Top Cabinet Enclosure with Gray Bottom17.8 in. L x 16.3 in. W x 9.3 in. H Polycarbonate Red Hinged Top Cabinet Enclosure with Red Bottom
            BrandCarlonSerpacSerpacSerpac
            Name3/4 in. x 100 ft. Electrical Nonmetallic Tubing Conduit Coil, Blue11.8 in. L x 10 in. W x 5.5 in. H Polycarbonate Clear Screw Top Cabinet Enclosure with Gray Bottom11.8 in. L x 10 in. W x 7.5 in. H Polycarbonate Clear Screw Top Cabinet Enclosure with Gray Bottom17.8 in. L x 16.3 in. W x 9.3 in. H Polycarbonate Red Hinged Top Cabinet Enclosure with Red Bottom
            Price
            $6273
            /roll
            $7503
            $8772
            $13130
            /box
            Ratings
            (83)
            (1)
            (1)
            (0)
            MaterialPVCPolycarbonatePolycarbonatePolycarbonate
            Trade Size (in.)3/4OtherOtherOther
            Packaging Type Consumer PackagingConsumer PackagingConsumer Packaging
            Box Type EnclosureEnclosureEnclosure
            Number of Gangs 000
            Number of Knockouts/Pryouts 000
            View ProductView ProductView ProductView Product