1500 CFM Black Power Roof Mount Attic Fan

  • Helps cool attics up 2,800 sq. ft. in size
  • Compact size with hemmed dome for a sleek look
  • High efficiency motor with adjustable thermostat
  • See More Details

Frequently Bought Together

+
+
Price:

Product Overview

More homes and businesses in the U.S. are protected by a GAF roof than by any other product. We are the leading roofing manufacturer in North America.

Nothing protects quite like a roof.

Nothing protects quite like a roof. That's why millions of Americans live, work, and play under quality products from North America's largest roofing manufacturer - GAF.

Always have a balanced ventilation system. The amount of exhaust ventilation should always be equal the amount of intake ventilation.

How much Ventilation do I need?

Include 1 sq. ft. of attic ventilation, evenly split between intake and exhaust, for every 300 sq. ft. of attic floor space.

Choosing the right attic ventilation for your home is very important. GAF offers a great selection of Master Flow and Cobra products.

What type of Ventilation do I need?

Review the ventilation options below to determine the best fit for your home application.

Available in both roof mount and gable mount, power attic vents exhaust the greatest volume of hot and/or humid air from the attic.

High efficiency Electric, Solar or Hybrid

Quickly removes large volumes of heat and moisture from your attic.

Cooler external air enters through vents lower on the eaves or soffits that “pushes” the hot/moist attic air out of the vents higher on the roof.

No electricity required

Allows excess heat and moisture to escape your attic without the need for electric hook-up.

Wind Turbines utilize the wind to pull heat and moisture from your attic and acts as a static exhaust vent when wind is still.

Wind-powered, smooth, and quiet operation

Utilizes the wind to pull heat and moisture from attic; acts as a static exhaust vent when wind is still.

Located at the lowest part of the roof, intake vents are a critical part of the attic ventilation system, allowing fresh air to flow into the attic

The most overlooked and critical part of attic ventilation

Allows cooler, fresh air to enter the attic at/near the soffits driving heat and moisture out higher exhaust vents.

Your home offers warning signs when your attic isn’t properly ventilated. You may recognize some of these signs in your own home.

5 Warning Signs

Here are some poor attic ventilation warning signs that you may recognize:

A possible cause of higher cooling costs could be insufficient attic ventilation, requiring the cooling system to run excessively.

1. Increased energy costs

Excess attic heat can cause your cooling system to work harder, raising your energy costs.

If you see that your shingles are dry or breaking, that could mean you have inadequate attic ventilation or you may need a new roof

2. Curling/cracking shingles

Inadequate ventilation can cause your roof shingles to curl and crack.

Moisture in the attic can become trapped and condense on rafters and insulation if not insulated properly. This can potentially increase energy costs

3. Roof decking moisture

Excess attic moisture can drip into attic insulation reducing effectiveness, even damaging ceilings below.

Stains or mold growth inside your home may be caused by inadequate attic ventilation. Excessive moisture in the attic allows mold and mildew to thrive

4. Attic mold/mildew

Excessive moisture can cause dangerous mold and mildew causing additional concerns.

Ice damming can cause water to enter the attic and house if you don’t have an adequate shingle underlayment or if the flashing has deteriorated.

5. Winter ice dams

Ice dams can cause expensive leaks and damage in attics, as well as living spaces.

The GAF Master Flow ERV6 Power Roof Vent is a great overall investment in attic ventilation. It can efficiently remove a larger volume of hot and/or humid air from your attic when compared to static ventilation. This in turn can help save money on your heating and cooling costs. The ERV6 model Power Roof Mount Vent can move air at a rate of up to 1500 cu. ft. per minute. It is designed for attic spaces up to 2800 sq. ft.
  • Energy efficient uses up to 55% less electricity than typical competitor's vents (based on GAF testing at 120-Volt)
  • Helps to reduce energy costs and helps prolong life of the roof and shingles
  • Galvanized steel construction for durability
  • Excellent for roof slopes 3:12 to 12:12
  • Heavy-duty internal screen helps prevent animal infestation
  • UL Listed
  • Miami-Dade County Product Control approved, State of Florida approved, and meets or exceeds the requirements of Texas Department of Insurance
  • Optional humidistat available (H1) - sold separately

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar Power Roof Vents

1000 CFM Mill Power Roof Mount Attic Fan
current product
Top Rated1500 CFM Black Power Roof Mount Attic Fan
15 Watt Solar Powered Roof Mount Attic Fan25-Watt 1450 CFM Black Solar Powered Attic Fan
BrandMaster FlowMaster FlowMaster FlowRemington Solar
Name1000 CFM Mill Power Roof Mount Attic Fan1500 CFM Black Power Roof Mount Attic Fan15 Watt Solar Powered Roof Mount Attic Fan25-Watt 1450 CFM Black Solar Powered Attic Fan
Price
Ratings
(129)
(210)
(27)
(176)
Power TypeElectric PoweredElectric PoweredSolar PoweredHybrid (Solar/Electric) Powered
FeaturesBuilt-in Screen,Thermostat ControlledBuilt-in Humidistat,Built-in Screen,PaintableAdjustable Solar Panels,Built-in ScreenAdjustable Solar Panels,Built-in Humidistat,Built-in Screen,Built-in Thermostat,Corrosion Resistant,Thermostat Controlled,UV Resistant,Weather Resistant,Wildlife Guard
Rough Opening Width (In.)15151514.5 in
Ventilation TypeRoofRoofRoofRoof
Wattage (watts)1601271525
Intake/ExhaustExhaustExhaustExhaustIntake/Exhaust
Rough Opening Height (In.)15151514.5 in
MaterialGalvanized SteelGalvanized SteelGalvanized SteelGalvanized Steel
View ProductView ProductView ProductView Product

Specifications

Dimensions

Coverage Area (Sq.Ft)
2800
Cut-Out Diameter (in.)
15
Net-Free Area (Sq. In.)
720
Product Depth (in.)
25
Product Height (in.)
9
Product Width (in.)
25
Rough Opening Height (In.)
15
Rough Opening Width (In.)
15

Details

Airflow (CFM)
1500
Amperage (amps)
1.65
Color Family
Black
Color/Finish
Black
Color/Finish Family
Black
Features
Built-in Humidistat,Built-in Screen,Paintable
Horsepower (hp)
1/9
Intake/Exhaust
Exhaust
Material
Galvanized Steel
Mounting Position
Roof Mount
Power Type
Electric Powered
Product Weight (lb.)
18
Recommended Sq. Ft.
2800
Returnable
90-Day
Ventilation Type
Roof
Voltage (volts)
120
Voltage (volts)
120
Wattage (watts)
127

Warranty / Certifications

Manufacturer Warranty
10-year Limited Parts/5-year Labor Warranty

Questions & Answers

106Questions33Answers

Can I put this on an on/off switch instead of a thermostat?

Asked by ARSN1 March 31, 2021
5
Answers

I left the thermostat connected on the 3 units I installed on my house and garage roofs and installed a switch in an electrical box supplying power to each individual unit. This allows both options for each unit.

Do they come with wire mesh to keep out rodents

Asked by Al December 4, 2020
5
Answers

Yes its a good quality metal mash, it will last for many years great product.

Can I speed control be added?

Asked by Rich November 24, 2020
4
Answers

No, this is a single sped motor, adding a speed control voids the warranty and may harm the fan. If you have any other inquiries about our Master Flow products please call Technical Services at 800-211-9612.

just installed.. live in Michigan temp is 45 degrees... will this work right away in cold temps

Asked by pearljam October 30, 2020
5
Answers

if you installed the in-line thermostat probably not. check the setting on it, it can be adjusted with a flat head screwdriver. if it's not running even at the minimum temp setting then it's most likely because it's not rated to run the fan at that low of a temperature. if you need to operate at a lower temp, remove the thermostat and wire it to a switch. then you can operate it manually.

This product comes with adjustable thermostate? Or will have to buy it separately?

Asked by Maria August 17, 2020
4
Answers

This model comes with a thermostat on;y ,Optional humidistat available (H1) - sold separately. If you have any other inquiries about our Master Flow products please call Technical Services at 800-211-9612.

What is the warranty period for this model ?

Asked by JackMC August 4, 2020
2
Answers

Never checked on warranty. I usually have to replace an electric fan motor about every 3 years. I set the temp to start fan at 110 degrees.

Can I connect this to my existing attic fan thermostat?

Asked by KSM July 29, 2020
1
Answer

It is possible if it is the correct Master Flow thermostat, although this product comes with a thermostat you will not need to reuse the existing one. If you have any other inquiries about our Master Flow products please call Technical Services at 800-211-9612.

Can this be installed on a rubber roof?

Asked by Chris July 23, 2020
2
Answers

No idea. I suggest you talk to a roofer or general contractor.

I see almost any question any one could ask but one, mine HOW BIG A HOLE NEEDED ,i need to replac...

Asked by jim July 10, 2020
3
Answers

The opening needed is 15" in diameter. If you have any other inquiries about our Master Flow products please call Technical Services at 800-211-9612.

The specs say a 15" rough opening is required. I have 16" on center rafters so the maximum diame...

Asked by Dave July 6, 2020
2
Answers

The 14.5 inch opening will work fine. If you have any other inquiries about our Master Flow products please call Technical Services at 800-211-9612.

1500 CFM Black Power Roof Mount Attic Fan - page 2

Customer Reviews

  • 4.5
    out of 211 reviews
  • 87% recommend this product
Filter by:
Showing 1-10 of 211 reviews
I've purchased Many of the GAF Master Flow power vents and several years ago I purchased them bec...
I've purchased Many of the GAF Master Flow power vents and several years ago I purchased them because the motor had lifetime warranty but I noticed on this one it's only a five year warranty so they're easy to install and simple to put Power to but I can't say how long it's going to last or its durability because it's only been installed for one week. If you have a difficult home to ventilate and you need positive airflow I highly recommend installing a power vent. They definitely remove heat for a minimal amount of cost. As a professional roofer of 30 years when the home has ventilation issues that ridge vent can't solve powered vents do the job. Solar Vents do work but they are subject to the Sun. In Texas it can be a hundred degrees and a cloudy day that solar vent will barely move.
by Texas
4 people found this helpful
Easy to install, well constructed, smooth and quiet running, only time will tell if it out-perfor...
Easy to install, well constructed, smooth and quiet running, only time will tell if it out-performs the 30 year old one that this replaced.
by WildWalter
Great product we love it in our pool house cooled it down 40° Before it was unbearable trying to ...
Great product we love it in our pool house cooled it down 40° Before it was unbearable trying to change clothes inside
by UpsPoolman
Easy to install, about an hour, quiet and moves a lot air!
Easy to install, about an hour, quiet and moves a lot air!
by Mark
4 people found this helpful
The product was easy to mount and wire. At first, it seemed that it wasn't working but when I ad...
The product was easy to mount and wire. At first, it seemed that it wasn't working but when I adjusted the thermostat a bit lower, it did kick on and run as described. It moves a lot of heat and humidity out of a big attic space. In my case, the hole in the roof from a previous turnstile stack exhaust was a little bit too small but gave me a starting point to use a reciprocating saw and make a larger hole in the roof surface, this was surely the most difficult part. I used elastomeric waterproofing to seal it after installation, then further coated the area with elastomeric white roof paint. Two storms later, still dry.
by DJ
15 people found this helpful
Easy installation, I watched a couple of youtube videos before doing the installation myself, and...
Easy installation, I watched a couple of youtube videos before doing the installation myself, and it was really easy. This product has worked for me so far, I installed it about a month ago and it has helped reduced the heat in my house. As far as lowering the electricity bill by reducing the amount of time the A/C is running, that is hard to tell because this last month has been hot, hot, Texas hot.
by nemesistiger
17 people found this helpful
I have not had it fully installed (the electrical has not been done yet), but one of the fans was...
I have not had it fully installed (the electrical has not been done yet), but one of the fans was delivered badly dented. There was already a hole int he roof, and I couldn't wait another week or more for a replacement, so the handyman pounded out the dent so that the unit will function. Not happy about that!
by fan
6 people found this helpful
Great Fan for the Money..
I'm very pleased with this fan, it is very inexpensive and powerful at the same time. Before installation I've learned to tighten the 4 bolts on the top of the hood before installation, for some reason they come loose from the factory and I did not know this until I had a client call me complaining about the fan making noise just 5 days after installation. Other than that, Great Product.
by Mike
24 people found this helpful
It met my needs exactly....
It met my needs exactly.
by 1906
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by HomeDepotCustomer
Showing 1-10 of 211 reviews