Brand | Square D | Siemens | Murray | Siemens |
Name | QO 30 Amp 2-Space 2-Circuit Indoor Main Lug Load Center | EQ 60 Amp 2-Space 4-Circuit Main Lug Surface Mount Load Center | 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center | EQ 60 Amp 2-Space 4-Circuit Main Lug Flush Mount Load Center |
Price | ||||
Ratings | (93) | (17) | (24) | (0) |
Maximum Amperage (amps) | 30 | 60 | 60 | 60 |
Indoor/Outdoor | Indoor | Indoor | Outdoor | Indoor |
Number of Spaces | 2 | 2 | 2 | 2 |
Mounting Type | Plug-On | Bolt On | Bolt On | Bolt On |
Number of Circuits | 2 | 4 | 4 | 4 |
Load Center Type | Main Lug | Main Lug | Main Lug | Main Lug |
Load center width (in.) | 3.81 | 6 | 5.9 | 11.6 |
Load center height (in.) | 6.72 | 11 | 6.0 | 6.9 |
View Product | View Product | View Product | View Product |
![]() | ![]() | ![]() | ![]() | |
Brand | Square D | Siemens | Murray | Siemens |
Name | QO 30 Amp 2-Space 2-Circuit Indoor Main Lug Load Center | EQ 60 Amp 2-Space 4-Circuit Main Lug Surface Mount Load Center | 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center | EQ 60 Amp 2-Space 4-Circuit Main Lug Flush Mount Load Center |
Price | ||||
Ratings | (93) | (17) | (24) | (0) |
Maximum Amperage (amps) | ||||
Indoor/Outdoor | ||||
Number of Spaces | ||||
Mounting Type | ||||
Number of Circuits | ||||
Load Center Type | ||||
Load center width (in.) | ||||
Load center height (in.) | ||||
View Product | View Product | View Product | View Product |
Yes, main lugs are rated for copper and aluminum wire. Please refer to wiring diagram link for wire gauge and torque information. https://www.downloads.siemens.com/download-center/Download.aspx?pos=download&fct=getasset&id1=BTLV_42110
Up to #2 AWG wire is accepted. Please see wiring diagram link. https://www.downloads.siemens.com/download-center/Download.aspx?pos=download&fct=getasset&id1=BTLV_42110
No it is for indoor use only. Outdoor equipment is designated with a 3R.
Please refer to wiring diagram link. Up to #2 AWG neutral wire is accepted in the large terminals. A bonding strap for the neutral ships separately in a bag for installation for service entrance applications. There is a provision for a field-installed ECGB5 equipment ground, if needed. https://www.downloads.siemens.com/download-center/Download.aspx?pos=download&fct=getasset&id1=BTLV_42110
Only Siemens labeled breakers, like the Type QP, are approved .
Yes, Type QT breakers are accepted in both breaker spaces.
No, E0204ML1060SU will not accept a 2pole ground fault breaker. Please consider E0204ML1125SCU instead.
Hello Kellie. Ground Lug Kit: ECGB5. Neutral - ECLNB14 (Main lug only); ECLNB16 (Main breaker Convertible neutral bar). Thank you
Yes, the QP series of breakers is approved for this load center
You must be using this for a stove or a range. Typically require a 6/2 with ground for this sort of application.