EQ 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center

  • Suitable for use as service entrance equipment
  • Aluminum Bus w/ factory installed Main Breaker; uses HA type Hub
  • Two extra circuits
  • See More Details

Frequently Bought Together

+
+
Price:

Product Overview

This EQ 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center is suitable for use as service entrance equipment. This unit features a NEMA 3R-rated enclosure to help protect against rainfall and ice formation. The single-phase center has a G90 hot-dipped, galvanized-carbon-steel enclosure that provides corrosion protection with an additional powder-coat finish.
  • G-90 hot-dipped galvanized carbon steel construction with a polyester-paint powder coating for corrosion protection
  • NEMA 3R-rated enclosure helps protect against rainfall and ice formation
  • G90 hot-dipped, galvanized-carbon-steel enclosure provides corrosion protection
  • Tangential knockouts eliminate the need for conduit offset
  • Copper buss bar is highly conductive
  • Single phase
  • 240-Volt
  • Compatible with type QP, QPH and HQP circuit breakers (not included)
  • ANSI certified and UL listed
  • Will not accommodate a double-pole GFCI or a circuit breaker with a shunt trip
  • Learn More About Electrical Panels Here in our Buying Guide.

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar Individual Subpanels

QO 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center with Non-Metallic Enclosure and NeutralPowerMark Plus 125 Amp 4-Space 8-Circuit Outdoor Single-Phase Main Lug Circuit Breaker PanelHomeline 125 Amp 4-Space 8-Circuit Outdoor Main Lug Load Center with Ground Bar
current product
EQ 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center
BrandSquare DGESquare DSiemens
NameQO 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center with Non-Metallic Enclosure and NeutralPowerMark Plus 125 Amp 4-Space 8-Circuit Outdoor Single-Phase Main Lug Circuit Breaker PanelHomeline 125 Amp 4-Space 8-Circuit Outdoor Main Lug Load Center with Ground BarEQ 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center
Price
Ratings
(20)
(98)
(22)
(6)
Maximum Amperage (amps)6012512560
Indoor/OutdoorOutdoorOutdoorOutdoorOutdoor
Number of Spaces2442
Mounting TypePlug-OnPlug-OnPlug-OnBolt On
Number of Circuits4884
Load Center TypeMain LugMain LugMain LugMain Lug
Load center width (in.)6.527.718.885.50
Load center height (in.)8.7913.214.89
View ProductView ProductView ProductView Product

Specifications

Dimensions

Load center depth (in.)
4
Load center height (in.)
9
Load center width (in.)
5.50

Details

Electrical Product Type
Main Lug/ Main Lug Kit
Indoor/Outdoor
Outdoor
Load Center Mounting Type
Surface
Load Center Type
Main Lug
Maximum Amperage (amps)
60
Mounting Type
Bolt On
NEMA Configuration
NEMA 3R
NEMA Configuration Receptacle
No Receptacle
Number of Circuits
4
Number of Spaces
2
Phase Type
1 Phase
Product Weight (lb.)
4.2 lb
Returnable
90-Day
Voltage (volts)
240

Warranty / Certifications

Certifications and Listings
ANSI Certified,UL Listed
Manufacturer Warranty
1 year

Questions & Answers

10Questions14Answers

will this work hooked up to a 50amp double breaker?

Asked by Tim April 4, 2021
2
Answers

If you are going to use standard 15 Amp duplex receptacles, you should use no greater than 20 Amp breakers with 12 guage copper wire, but check your local building codes, GFI breakers, or GFI outlets may be required depending on the patio construction. It should work with two 20 Amp standard breakers or four slim breakers. Get a permit from your local building department, the will help with proper and safe installation.

Hi, Siemens. Will the Q21530CT breaker (30 Double Two 15-Amp Single Pole Circuit Breaker) work w...

Asked by Edmond February 6, 2021
1
Answer

Yes, it will. Please see the wiring diagram in the link below where the QT is listed. Note W0204ML1060U is just the retail-packaged version of W0204ML1060. https://www.downloads.siemens.com/download-center/Download.aspx?pos=download&fct=getasset&id1=BTLV_39542

Will this work for a 60Amp GFCI breaker for hot tub install

Asked by bazz1 October 11, 2020
1
Answer

W0204ML1060U will not accommodate a 2-pole GFCI. Consider W0204ML1125CU which can accommodate 2-pole GFCI breaker up to 60A. Please see link. https://www.downloads.siemens.com/download-center/Download.aspx?pos=download&fct=getasset&id1=BTLV_50368

Help Siemens. Purchased this box along with 783643148383 Model Q230U Type QP 30A double pole brea...

Asked by FalkTheHawk July 13, 2020
2
Answers

Must have purchase the wrong breaker because mine fit perfectly. Installed breaker box 2 weeks ago.

Will this takes QT Circuit Breaker? Like Model # Q21515CT

Asked by Bill May 6, 2020
1
Answer

Yes this load center will take a QT style breaker https://www.downloads.siemens.com/download-center/Download.aspx?pos=download&fct=getasset&id1=BTLV_50363

How about a 2 pole 40 amp siemens QPF type GFCI breaker?

Asked by Deantroi October 7, 2018
1
Answer

W0204ML1060 does not accommodate a 2-pole GFCI breaker. Consider W0408L1125SPA50 which can accommodate a 2-pole GFCI breaker up to 50A and has 2 additional spaces.

Description says it has a factory installed main breaker. I can't see this in the picture; and w...

Asked by runnerman May 14, 2018
2
Answers

Sorry, W0204ML1060U is a main lug load center. The main breaker is sold separately. We will get this fixed. To download the wiring diagramfor this item go to link below and click on "Downloads" and enter W0204ML1060 in the search box. https://w3.usa.siemens.com/powerdistribution/us/en/speedfax-product-catalog/Pages/speedfax-product-catalog.aspx

will a Siemens QF130 30-Amp 1 Pole 120-Volt Ground Fault Circuit Interrupter work on this pannel?

Asked by Donniecat July 8, 2016
2
Answers

Yes, it will work on this panel.

60 or 120 total amps

Asked by WW January 8, 2016
1
Answer

Hi WW, The bus in this panel is rated for 60 amps. You can use a two pole 60 amp breaker if needed. It is recommended that you consult a professional electrician for install.

will this box take (2) 220v 20 amp breakers

Asked by Pete June 9, 2014
1
Answer

Hi Pete, This Siemens W0204ML1060U outdoor panel is designed to fit only two 1" circuit breakers. You have the option of using 2 single pole breakers, or 1 double pole breaker. Thank you.

EQ 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center - page 2

Customer Reviews

  • 4.7
    out of 6 reviews
  • 100% recommend this product
Filter by:
Showing 1-6 of 6 reviews
Worked great for a 30 amp sub-panel for a 120 v RV extension cord plugin.
Worked great for a 30 amp sub-panel for a 120 v RV extension cord plugin.
by Ric
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by HomeDepotCustomer
Love murray/siemens products. Great products and easy to find....
Love murray/siemens products. Great products and easy to find.
by Rudy
It is an excellent exterior electrical panel, well insulated, spacious...
It is an excellent exterior electrical panel, well insulated, spacious and easy to work with.
by HomeDepotCustomer
Dislike the way it is set up to either hold the cover on with a screw or position the clip to loc...
Dislike the way it is set up to either hold the cover on with a screw or position the clip to lock with a pad lock. Very cheap and flimsy.
by Mike
Replaced the one I had. looks and works great....
Replaced the one I had. looks and works great.
by HomeDepotCustomer
Response from SIEMENS Product ExpertAug 30, 2018
We appreciate your business! SIEMENS
Showing 1-6 of 6 reviews