Internet #100196368

Model #HOM48L125GRB

Store SKU #220796

Homeline 125 Amp 4-Space 8-Circuit Outdoor Main Lug Load Center with Ground Bar

  • For residential or commercial power distribution
  • Compatible with Square D Homeline Standard circuit breakers
  • Outdoor, ground bar, and aluminum bus bar included
  • See More Details

Frequently Bought Together

+
+
Price:
$3190

Product Overview

The Square D Homeline 125 Amp 4-Space 8-Circuit Outdoor Convertible Main Lugs Load Center with Ground Bar is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings.
  • Includes a factory-installed PK7GTA ground bar and rainproof outdoor cover
  • Accommodates plug-on secondary surge arrestor (sold separately)
  • Main feeders terminate from the top, feeders can enter from any direction, however, device cannot be rotated
  • Single phase
  • Rated 120/240 VAC and 10,000 AIR short circuit current rating
  • Rainproof cover features a stainless steel hasp that is easily padlocked for safety from theft
  • Thermoplastic interior assembly is among the most rugged in the industry
  • Slot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque
  • Equipment ground bar is included
  • Learn More About Electrical Panels Here in our Buying Guide.
  • California residents

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar Individual Subpanels

QO 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center with Non-Metallic Enclosure and Neutral
current product
Homeline 125 Amp 4-Space 8-Circuit Outdoor Main Lug Load Center with Ground Bar
QO 100 Amp 6-Space 12-Circuit Outdoor Main Lug Load Center with CoverQO 100 Amp 8-Space 16-Circuit Outdoor Main Lug Load Center with Cover
BrandSquare DSquare DSquare DSquare D
NameQO 60 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center with Non-Metallic Enclosure and NeutralHomeline 125 Amp 4-Space 8-Circuit Outdoor Main Lug Load Center with Ground BarQO 100 Amp 6-Space 12-Circuit Outdoor Main Lug Load Center with CoverQO 100 Amp 8-Space 16-Circuit Outdoor Main Lug Load Center with Cover
Price
$2573
$3190
$3827
$6696
Ratings
(19)
(18)
(42)
(42)
Maximum Amperage (amps)60125100100
Indoor/OutdoorOutdoorOutdoorOutdoorOutdoor
Number of Spaces2468
Mounting TypePlug-OnPlug-OnPlug-OnPlug In
Load Center TypeMain LugMain LugMain LugMain Lug
Number of Circuits481216
Load center width (in.)6.528.888.888.88
Load center height (in.)8.7914.812.6512.65
Number of Phases 1
View ProductView ProductView ProductView Product

Specifications

Dimensions

Load center depth (in.)
4.27
Load center height (in.)
14.8
Load center width (in.)
8.88

Details

Electrical Product Type
Main Lug/ Main Lug Kit
Indoor/Outdoor
Outdoor
Load Center Mounting Type
Surface
Load Center Type
Main Lug
Maximum Amperage (amps)
125
Mounting Type
Plug-On
Number of Circuits
8
Number of Spaces
4
Phase Type
1 Phase
Product Weight (lb.)
11.24
Returnable
180-Day
Voltage (volts)
120/240

Warranty / Certifications

Certifications and Listings
UL Listed
Manufacturer Warranty
Square D warrants its single phase load centers, in a residential application, to be free from defects in material and workmanship under normal care and proper usage for a period of 10 years from the date of installation for HOMELINE load centers when used with the appropriate Square D HOMELINE branch circuit breakers.

Questions & Answers

18Questions20Answers

How do you get it open in order to replace the fuse?

Asked by ttt August 15, 2020
2
Answers

No offense, but the wording of your question suggests you really should get an electrician to work on it. It uses breakers, not fuses. You unscrew the two silver screws in front to remove the cover.

Will this box accept two 2-pole 220V breakers?

Asked by Mike July 21, 2020
2
Answers

Yes, I have 2, 2-pole 220Volt 40amp breakers in mine

I have 200 amp service. I need this to power my workshop, my barn, and my greenhouse. The shop ha...

Asked by Camiemom August 15, 2018
2
Answers

You have to focus on the breaker at the house feeding the 6 gauge wire. That breaker protects the wire from burning up. You can put a box at the end that can handle a higher load you just won’t be able to draw more current than the breaker sourcing the run to it. Given the loads you describe it doesn’t sound like you will be able to run them all at the same time, maybe only one at a time, but that is ok if that’s all you want. Hard to know your situation but bigger wire to your shop, barn, and greenhouse would be more convenient because your source breaker could be larger and you could run more. For example my compressor would consume that entire circuit when running. I do have this box and run it as an 80 amp sub panel (2 40 amp breakers)

What is the SMALLEST the feeder lugs will accept, I want to use 30A feeder with 10AWG but alot of...

Asked by Jeremy March 4, 2018
5
Answers

This model can use 12-2/0 AL or 14-2/0 CU.

I will need a 125A outdoor main breaker box that has a few spaces for 20A breakers in it and will...

Asked by Rocky January 19, 2018
1
Answer

Suggested product is HOM816M125PRB. Outdoor load center with 125A installed main. We do not offer with fewer spaces. Regards, Customer Care

What 125A and/or 100A main breaker should be used with this unit?

Asked by Rocky January 18, 2018
3
Answers

This is a lug center which doesn't have a main breaker. It will support up to 125 amps of load out of the box. So you could use a 125 amp breaker or several smaller breakers to protect various branch circuits.

what size wire do I use for 125 amp it will be in 1 1/2" conduit

Asked by cs June 26, 2017
1
Answer

Hello, The HOM48L125GRB will accept a wire size of #12-2/0 AL or #14-2/0 CU wire. Regards, Customer Care Center

Can I use a 50A main breaker for this panel rather than a 125A?

Asked by Dpershing April 14, 2017
2
Answers

The answer I read from the previous Homelite Rep did not seem to answer ur question correctly..........I am assuming u mean that u will have a 50 amp. main breaker in another master panel to feed this subpanel..........as I understand this panel it is more of a sub panel than a master panel since u only have 4 positions and the power line inputs are wired directly to the terminal blocks with the lug screws shown in the blown up picture of the interior.......this panel can handle loads up to 125 amp so yes if u feed a 50 amp breaker in ur main panel to this subpanel with the proper guage wire then u can use it to supply 2 ...20 amp 240 v. breakers............or even have an 80 amp breaker in the main and feed 2.....40 amp 240 v breakers in this sub panel

What are dimensions ?

Asked by Andy November 28, 2016
1
Answer

The dimensions are 14.8''H x 8.88''W x 4.27''D.

Can this box be connected to the outside meter box and used for a main outside disconnect for the...

Asked by Huck November 3, 2016
1
Answer

Yes. Please confirm application with local authorities having jurisdiction to ensure all local code requirements are met.

Homeline 125 Amp 4-Space 8-Circuit Outdoor Main Lug Load Center with Ground Bar - page 2

Customer Reviews

  • 4.5
    out of 19 reviews
  • 100% recommend this product
5star-icon11
4star-icon5
3star-icon3
2star-icon0
1star-icon0
Filter by:
Showing 1-10 of 19 reviews
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by HomeDepotCustomer
Vertical orientation gives plenty of room for the much larger...
Vertical orientation gives plenty of room for the much larger AFCI/GFCI circuit breakers while still being able to route wires in from the bottom. Instructions were clear; all essential hardware was included.
by SCOTT
It worked very well for my needs...
It worked very well for my needs
by HomeDepotCustomer
by Bryan
4 Star Review
Rating provided by a verified purchaser
by HomeDepotCustomer
I haven't installed it yet...
I haven't installed it yet
by dana
I personally don't know anything in electricity, but the technician...
I personally don't know anything in electricity, but the technician who installed it in my house was satisfied.
by Flora
Everything I needed in an outdoor panel. Room for 2...
Everything I needed in an outdoor panel. Room for 2 double-pole breakers.
by Joe
1 person found this helpful
Product is as described.
Product is as described.
by CandS
Very good breaker box, it is everything it was advertised to be, well construed.
Very good breaker box, it is everything it was advertised to be, well construed.
by Shorty