I just installed one of these to replace my Honeywell R8184G 4009, which it will replace and it w...
I just installed one of these to replace my Honeywell R8184G 4009, which it will replace and it works great. Was also cheaper than the simple electro-mechanical old one. Its universal so it will work with any cad cell setup. My only complaint was the directions that didnt give clear instructions for my particular setup. One noteworthy thing is that the limit connection must be connected to Line 1 on a direct thermostat setup like mine. The only other issue I had was that in the installer setup the setting for using "TT" seems to be reversed, no means yes and yes means no, so basically if you enable using the TT terminals it will run forever until it triggers thermal protection, but if you dont it works fine and listens to the thermostat. Someone should fix that or clarify it in the manual, the definitions of some of the settings are pretty lacking. A simple, this does this, and that does that, this connection is for this.... that type of thing would be great for more amateur installers and would probably help more than a few professionals.
Besides the manual, its good! My furnace is up and running again and now I've got a neat real time OHM meter for my CAD sensor, this will enable me to monitor sensor degradation over time.
by
Recommended
3 found this review helpful
Apr 20, 2023
by
Verified Purchase
Feb 1, 2023
by
Verified Purchase
Oct 16, 2022
by
Verified Purchase
Jun 9, 2022
Works well, until it doesnt
Have been replacing about once a year. Works great - until it doesnt anymore. I would recommend using in emergency only and get your manufacturer's replacement
by
Verified Purchase
Recommended
May 12, 2022
I returned it for a refund, I didn’t need it...
I returned it for a refund, I didn’t need it after all
by
Verified Purchase
Mar 17, 2021
Easy setup works great wired right into my furnace...
Easy setup works great wired right into my furnace
by
Verified Purchase
Mar 8, 2021
The cross reference that the showed online did not match...
The cross reference that the showed online did not match the ones on box. Very little information to go on as far as replacing old red popup/push button unit. If anyone needs helo using on an oil fired forced air unit, I figure the wiring out.
by
Verified Purchase
Mar 6, 2021
Easy to wire up and great feature being able to...
Easy to wire up and great feature being able to see the parameters and lock outs.
by
Verified Purchase
Mar 6, 2021
Perfect upgrade from the original .
Perfect upgrade from the original .
by
Verified Purchase
Recommended
Feb 20, 2021
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by
Verified Purchase
Dec 6, 2020
Installed easily replacing Becket control....
Installed easily replacing Becket control.
by
Verified Purchase
May 6, 2020
Fit perfectly and came with jumper wires to make connections....
Fit perfectly and came with jumper wires to make connections.
by
Verified Purchase
Oct 30, 2019
What a pain in the butt. I finally got this thing wired properly and then it went into a hard loc...
What a pain in the butt. I finally got this thing wired properly and then it went into a hard lockout mode. Troubleshooting guide sucks. I ended up returning it.
by
Verified Purchase
May 1, 2018
Great if you want some clues as to why your furnace isn't acting as it should.
Great if you want some clues as to why your furnace isn't acting as it should.
by
Verified Purchase
Recommended
Apr 10, 2018
This primary control provides the reasons the furnace has an issue. I got it just for that featu...
This primary control provides the reasons the furnace has an issue. I got it just for that feature to be able to identify an intermittent "tripping" and within a couple of days, I had the answer and got the part to correct the issue. The only issue with it, is if your furnace doesn't have a wire for the limit blade, the tech will need to splice the hot for it. The instructions do not talk about this issue. Other than that, it was easy to install.
by
Verified Purchase
Recommended
Mar 18, 2018
IF YOU CAN READ A PRINT AND DO LIGHT WIRING I WOULD RECOMMEND THIS TO ANYONE WANTING MORE CONTROL...
IF YOU CAN READ A PRINT AND DO LIGHT WIRING I WOULD RECOMMEND THIS TO ANYONE WANTING MORE CONTROL OVER HOW THEIR FURNACE FUNCTIONS,,,,AND QUICK DIAGNOSTICS,,,,YOU CAN SAVE A TON JUST BEING ABLE TO DO THE WORK YOURSELF,,,,,A + + + + + I HAVE USED THIS MODEL SINCE IT CAME OUT AND WILL NEVER GO BACK TO THE " GRAY BOX "
by
Recommended
Feb 14, 2018
Had a heater repaitcompany install it. Would not work. They...
Had a heater repaitcompany install it. Would not work. They tried everything. Finally went and got a beckett. Installed in 10 minutes was up and running. Thankful the company didnt charge me the hour plus of labor messing with it. Tech said the suck and dont work.
by
Verified Purchase
Jan 25, 2018
5 Star Review
Rating provided by a verified purchaser
by
Verified Purchase
Jan 17, 2018
3 Star Review
Rating provided by a verified purchaser
by
Verified Purchase
Dec 12, 2017
Skill set to install from 1 to 10 a 5...
Skill set to install from 1 to 10 a 5 it works great and now with the led display I no what's wrong and what zone is not working system is working perfect and the price was just wright.
I had no idea Home Depot sold this product glad I checked I feel better buying From Home Depot.
Thanks
by
Verified Purchase
Apr 6, 2017
2 Star Review
Rating provided by a verified purchaser
by
Verified Purchase
Dec 9, 2015
Replaced R7148 1024 Primary Control
I used this to replace a Honeywell R7148 1024 with the #7248
Like the diagnostic features of the read out, great for trouble shooting.
I used it on a Beckett Forced Air Furnace Unit, Had to feed limit switch connection with a constant 120 volt on 7248 Primary Control to fake it out that Limit switch was closed. So unit would operate as per Honeywell.Took feed from on/off disconnect switch on unit of side.